clark磁力驱动泵 CLARK SOLUTIONS AM Series Magnetic Drive Chemical Pumps Flow Rates to 55 GPM, Pressures to 22 PSI DESCRIPTION The AM series chemical pumps are centrifugal, horizontal axis, close-coupled type. The bodies are entirely built with reinforced thermoplastic polymers. Materials for the internal components include ceramic oxides, HD carbon and fluorinated elastomers. Any fluid contact with metallic pump parts is avoided. These chemical pumps are an excellent choice for small scale chemical pumping applications. FEATURES “Hermetic” Pump A drive magnet assembly (item 7 of cut away dwg.) is driven by the motor shaft. This magnetic field acts on the magnet that is molded into the impeller assembly (item 4). The rear casing (item 2) isolates the drive mechanism from the impeller assembly and the fluid media. 1) Volute Casing 6) SS Screws 2) Rear Casing 7) Drive Magnet Assembly 3) O-Ring Gasket 8) Support 4) Centrifugal Impeller 9) Flange for NEMA Motor 5) a/b Guide Bushings 10) Electrical Motor Safety & Life The magnetic drive system, which excludes any type of rotating seal, extends pump life. The only seal required is a static o-ring gasket between the volute casing and rear casing. The “R” version of the pump (see tables 2&3) has materials that tolerate dry running for 15 minutes to hours (depending on operating conditions and materials selected). Versatility & Performance Two housing materials, style WR, glass fiber reinforced (30%) Polypropylene, and style GF, Ethylene-ChloroTrifluoroEthylene carbon fiber filled (20%) are offered along with a choice of internal materials. Depending on material choice, the pumps handle applications from clean water to waste and slightly abrasive liquids, strong alkali or salts such as sodium hypochlorite, and acids such as chromix, nitric, sulphuric, etc.(see compatibility chart ). The mechanical properties of the reinforced housing materials allow the use of the pumps with fluids containing solids with medium grade of abrasion. For example a pump supplied with “X” internal materials (see table ) can handle solids up to an index hardness of Mohs 4, a maximum quantity in weight of 5%, and a maximum size of 0.25 mm. A selection of impellers accommodates a range of liquid specific gravities. MATERIALS Media Compatibility Medium WR GF V K Cold mineral acids ++ ++ + + Hot mineral acids 0 ++ - + Cold oxidizing acids - ++ + + Hot oxidizing acids - ++ 0/- + Cold inorganic salts ++ ++ + + Hot inorganic salts + ++ + + Cold inorganic bases ++ ++ -(*) + Hot inorganic bases ++ ++ -(*) + Cold alogens - + + + Hot alogens - + - + Cold aliphatic solvents + + + + Hot aliphatic solvents - 0 0/- + Cold aromatic solvents - + 0/- + Hot aromatic solvents - 0 - + Cold functional aromatic solvents - + - + Hot functional aromatic solvents - 0 - + Cold chlorinated solvents - + - + Hot chlorinated solvents - 0 - + Cold alcohols ++ ++ -(*) + Hot alcohols + + -(*) + Cold ethers - + - + Hot ethers - + - + Cold ketones + + + Hot ketones 0 0 -(*) + Cold amines + + -(*) + Cold polymer solvents ++ 0 + + ++= Excellent + =Good 0=Moderate -=Not Resistant (*)=Use EPDM ABBREVIATION LEDGER GFR/PP(WR)- Glass reinforced polypropylene CFF/E-CTFE(GF)- EthylenchloroTrifluoroEthylene carbon filled(20%) Carb. H.D.- High density carbon SiC- Silicon Carbide CER- Alumina ceramic at 99.7%- hi purity FKM(V)- Fluorinated elastomer FFKM(K)- Perfluor elastomer EPDM- EthylenePropylene rubber NPT m- Male NPT NPT f- Female NPT ND- Nominal diameter ANSI- Ref. flange ANSI B 16.5- flat face Table1 - Case Materials Version Reinforced Polymers Process Min Temp. Process Max. Temp. Ambient temp. WR GFR-PP -5oC (23oF) 80oC (176oF) 0-40oC (32...104oF) GF CFF-E-CTFE -30oC (-22oF) 110oC (230oF) -20-40oC (-4...104oF) Table2 - Materials Model AM45 Pump Model AM-45-WR AM-45-GF Pump Version R R Volute Casing GFR-PP CFF-E-CTFE Rear Casing Centrifugal Impeller Guide Bushing Carb. HD Carb. HD Shaft CER CER Thrust Bushing CER CER O Ring Gasket FKM (1) FKM (1) ; (2) Screws 304 SS 304 SS Table3 - Materials Models AM250P, 350P, 500P Pump Model AM-XXXP-WR AM-XXX-GF Pump Version R X1 R X2 Volute Casing GFR-PP CFF-E-CTFE Rear Casing Centrifugal Impeller Guide Bushing Carb. HD Carb. HD Shaft CER CER SiC SiC Thrust Bushing CER CER SiC SiC O Ring Gasket FKM (1) FKM (1) ; (2) Screws 304 SS 304 SS Upon request: (1) EPDM and (2) FFKM FLOW DATA Table4 - Impeller Selection Liquid Specific Gravity Limits At Max Flow Impeller Specific Gravity Limit (kg/dm3) H 1.1 K 1.4 L 1.9 Actual RPM at max. capacity Pump Model 45 250P 350P 500P RPM 3400 3200 3200 3300 Flow Curves are for water at 20°C SPECIFICATIONS Pump Model AM45 AM250P AM350P AM500P Inlet 1/2” NPT m 3/4” NPT f 1” NPT m 1-1/4” NPT m Outlet 3/8” NPT m 3/4” NPT m 1” NPT m 1” NPT m ANSI Flanges N/A N/A 1” 1” Power 45W 1/3 HP 1/2 HP 3/4 HP Type single-phase three-phase three-phase three-phase Voltage 208-230 208/230-460 Motor Size Special NEMA 56C Max Inlet Pressure 22 PSI Medium Viscosity <20 cSt Weight 8.8 lb 28.5 lb 31 lb 37.5 lb Model AM45 (mm) AM45 (inches) a1 34 1-11/32 L 225 G 120 4-3/4 Q 40 1-9/16 h1 60 2-3/8 h2 75 2-31/32 S Ø 9.5 Ø 3/8 r 90 3-9/16 R Ø 102.3 Ø 4 m1 40 1-9/16 n1 100 3-15/16 Dimensions in inches Model 250P 350P 500P a1 2-7/16 2-7/16 2-7/16 a1.1 2-7/16 2-7/16 2-7/16 L 12-1/4 12-1/4 12-1/4 HD 6-1/2 6-1/2 6-1/2 Q 1-27/32 1-15/16 2-3/32 h1 3-1/2 3-1/2 3-1/2 h2 3-15/16 3-15/16 3-15/16 h2.1 3-15/16 3-15/16 3-15/16 S 11/32 11/32 11/32 r 8-3/16 8-3/16 8-3/16 r1 5-5/8 5-5/8 5-5/8 R 5-3/4 5-3/4 5-3/4 m1 3 3 3 n1 4-7/8 4-7/8 4-7/8 KM 2-3/4 3-1/8 3-1/2 KA 2-3/4 3-1/8 3-1/2 dxz 5/8 x 4 5/8 x 4 5/8 x 4 Flanges are per ANSI B 16.5- Flat Face ORDERING INFORMATION AM-A-B-C-D-E-F-G-H-I EXAMPLE: AM-250P-GF-H-V-R-N-U-N-3 A= Model B= Pump Body (Table 2) C=Impeller (Table 4) D= O-Ring Gasket E=Materials (Tables 2&3) F=Connections G=Motor H=Motor Detail I=Motor Phases 45 WR GK H K L V=FPM E=EPDM K=FFKM R X N=NPT A=ANSI Flange U=NEMA N=Standard S=Special Voltage E=Ex-Proof 0=Without Motor 1=Single Phase 3=Three Phase 250P 350P 500P For assistance call 978-568-3400 pumps | valves | instrumentation | new products | contact clark | site/product directory | enewsletter | home Search in Entire SiteOther About this search engine.

clark磁力驱动泵

的详细介绍
clark磁力驱动泵
 
 
AM Series Magnetic Drive Chemical Pump CLARK SOLUTIONS
AM Series Magnetic Drive Chemical Pumps
Flow Rates to 55 GPM, Pressures to 22 PSI

DESCRIPTION
The AM series chemical pumps are centrifugal, horizontal axis, close-coupled type. The bodies are entirely built with reinforced thermoplastic polymers. Materials for the internal components include ceramic oxides, HD carbon and fluorinated elastomers. Any fluid contact with metallic pump parts is avoided.

These chemical pumps are an excellent choice for small scale chemical pumping applications.
 
FEATURES
“Hermetic” Pump
A drive magnet assembly (item 7 of cut away dwg.) is driven by
the motor shaft. This magnetic field acts on the magnet that is
molded into the impeller assembly (item 4). The rear casing
(item 2) isolates the drive mechanism from the impeller
assembly and the fluid media.

Chemical Pump AMSeries Magnetic Drive Centrifugal chemical pump

1) Volute Casing
6) SS Screws
2) Rear Casing
7) Drive Magnet Assembly
3) O-Ring Gasket
8) Support
4) Centrifugal Impeller
9) Flange for NEMA Motor
5) a/b Guide Bushings
10) Electrical Motor

Safety & Life
The magnetic drive system, which excludes any type of rotating seal, extends
pump life. The only seal required is a static o-ring gasket between the volute
casing and rear casing. The “R” version of the pump (see tables 2&3) has
materials that tolerate dry running for 15 minutes to hours (depending on
operating conditions and materials selected).


Versatility & Performance
Two housing materials, style WR, glass fiber reinforced (30%) Polypropylene,
and style GF, Ethylene-ChloroTrifluoroEthylene carbon fiber filled (20%) are
offered along with a choice of internal materials. Depending on material choice,
the pumps handle applications from clean water to waste and slightly abrasive
liquids, strong alkali or salts such as sodium hypochlorite, and acids such as
chromix, nitric, sulphuric, etc.(see compatibility chart ). The mechanical
properties of the reinforced housing materials allow the use of the pumps
with fluids containing solids with medium grade of abrasion. For example a
pump supplied with “X” internal materials (see table ) can handle solids up
to an index hardness of Mohs 4, a maximum quantity in weight of 5%, and
a maximum size of 0.25 mm.

A selection of impellers accommodates a range of liquid specific gravities.

/AMSeriesGroup

 
MATERIALS

Media Compatibility
Medium     WR GF V K
Cold mineral acids  ++ ++ + +
Hot mineral acids 0 ++ - +
Cold oxidizing acids - ++ + +
Hot oxidizing acids - ++ 0/- +
Cold inorganic salts ++ ++ + +
Hot inorganic salts + ++ + +
Cold inorganic bases ++ ++ -(*) +
Hot inorganic bases  ++ ++ -(*) +
Cold alogens - + + +
Hot alogens - + - +
Cold aliphatic solvents + + + +
Hot aliphatic solvents  - 0 0/- +
Cold aromatic solvents - + 0/- +
Hot aromatic solvents - 0 - +
Cold functional aromatic solvents - + - +
Hot functional aromatic solvents - 0 - +
Cold chlorinated solvents - + - +
Hot chlorinated solvents  - 0 - +
Cold alcohols ++ ++ -(*) +
Hot alcohols + + -(*) +
Cold ethers - + - +
Hot ethers - + - +
Cold ketones + +   +
Hot ketones 0 0 -(*) +
Cold amines + + -(*) +
Cold polymer solvents ++ 0 + +
++= Excellent    + =Good    0=Moderate    -=Not Resistant
(*)=Use EPDM


ABBREVIATION LEDGER

GFR/PP(WR)- Glass reinforced polypropylene
CFF/E-CTFE(GF)- EthylenchloroTrifluoroEthylene carbon filled(20%)
Carb. H.D.- High density carbon
SiC- Silicon Carbide
CER- Alumina ceramic at 99.7%- hi purity
FKM(V)- Fluorinated elastomer
FFKM(K)- Perfluor elastomer
EPDM- EthylenePropylene rubber
NPT m- Male NPT
NPT f- Female NPT
ND- Nominal diameter
ANSI- Ref. flange ANSI B 16.5- flat face


Table1 - Case Materials

Version   Reinforced Polymers Process Min Temp.
Process Max. Temp.
Ambient temp.
WR GFR-PP -5oC (23oF) 80oC (176oF) 0-40oC (32...104oF)
GF CFF-E-CTFE  -30oC (-22oF) 110oC (230oF)  -20-40oC (-4...104oF)


Table2 - Materials Model AM45

Pump Model AM-45-WR AM-45-GF
Pump Version R R
Volute Casing  GFR-PP CFF-E-CTFE
Rear Casing
Centrifugal Impeller
Guide Bushing Carb. HD Carb. HD
Shaft CER CER
Thrust Bushing CER CER
O Ring Gasket FKM (1) FKM (1) ; (2)
Screws 304 SS 304 SS


Table3 - Materials Models AM250P, 350P, 500P

Pump Model AM-XXXP-WR AM-XXX-GF
Pump Version R X1 R X2
Volute Casing  GFR-PP CFF-E-CTFE
Rear Casing
Centrifugal Impeller
Guide Bushing Carb. HD   Carb. HD  
Shaft CER CER SiC SiC
Thrust Bushing CER CER SiC SiC
O Ring Gasket FKM (1) FKM (1) ; (2)
Screws 304 SS 304 SS

Upon request: (1) EPDM and (2) FFKM


FLOW DATA

Table4 - Impeller Selection

Liquid Specific Gravity Limits At Max Flow
Impeller Specific Gravity Limit (kg/dm3)
H 1.1
K 1.4
L 1.9


Actual RPM at max. capacity
Pump Model 45 250P 350P 500P
RPM 3400 3200 3200 3300


Flow Curves are for water at 20°C



SPECIFICATIONS

Pump Model AM45 AM250P AM350P AM500P
Inlet 1/2” NPT m  3/4” NPT f 1” NPT m 1-1/4” NPT m
Outlet 3/8” NPT m 3/4” NPT m  1” NPT m  1” NPT m
ANSI Flanges N/A N/A 1” 1”
 Power 45W 1/3 HP 1/2 HP 3/4 HP
Type  single-phase three-phase three-phase three-phase
Voltage 208-230 208/230-460
Motor Size Special NEMA 56C
Max Inlet Pressure  22 PSI
Medium Viscosity <20 cSt
Weight 8.8 lb 28.5 lb 31 lb 37.5 lb






Model AM45 (mm) AM45 (inches)
a1 34 1-11/32
L 225  
G 120 4-3/4
Q 40 1-9/16
h1 60 2-3/8
h2 75 2-31/32
S Ø 9.5 Ø 3/8
r 90 3-9/16
R Ø 102.3  Ø 4
m1 40 1-9/16
n1 100 3-15/16


Dimensions in inches
Model 250P 350P 500P
a1 2-7/16 2-7/16 2-7/16
a1.1 2-7/16 2-7/16 2-7/16
L 12-1/4 12-1/4 12-1/4
HD 6-1/2 6-1/2 6-1/2
Q 1-27/32 1-15/16  2-3/32
h1 3-1/2 3-1/2 3-1/2
h2 3-15/16 3-15/16 3-15/16
h2.1 3-15/16 3-15/16 3-15/16
S 11/32 11/32 11/32
r 8-3/16 8-3/16 8-3/16
r1 5-5/8 5-5/8 5-5/8
R 5-3/4 5-3/4 5-3/4
m1 3 3 3
n1 4-7/8 4-7/8 4-7/8
KM  2-3/4  3-1/8  3-1/2
KA  2-3/4  3-1/8 3-1/2
dxz 5/8 x 4 5/8 x 4 5/8 x 4
Flanges are per ANSI B 16.5- Flat Face


ORDERING INFORMATION

AM-A-B-C-D-E-F-G-H-I
EXAMPLE: AM-250P-GF-H-V-R-N-U-N-3

A= Model B= Pump Body
(Table 2)
C=Impeller
(Table 4)
D=
O-Ring Gasket
E=Materials
(Tables 2&3)
F=Connections  G=Motor  H=Motor Detail I=Motor Phases
45 WR

GK

H

K

L

V=FPM

E=EPDM

K=FFKM

R

X

N=NPT
A=ANSI Flange
U=NEMA N=Standard

S=Special Voltage

E=Ex-Proof

0=Without Motor

1=Single Phase

3=Three Phase

250P
350P
500P




For assistance call 978-568-3400
 
pumps | valves | instrumentation | new products | contact clark | site/product directory | enewsletter | home

Search in About this search engine.


产品留言


  相关产品  
  美国 SUNDYNE 胜达因 磁力泵 all 001 Caster m 系列 all
美国 SUNDYNE 胜达因 磁力泵 all 002 caster 系列 all
美国 SUNDYNE 胜达因 磁力泵 all 003 caster mch 系列 all
美国 SUNDYNE 胜达因 磁力泵 all 004 castr mc-sp 系列 all
美国 SUNDYNE 胜达因 磁力泵 all 005 caster mta 系列 all
 

上海宏钲机械设备有限公司   电话:021-52584926 biye77@gmail.com  传真:021-52584992
地址:上海市番禺路390号时代大厦1201室      邮编:200052       网站管理入口
网络推广:泵阀网 技术支持:
主营产品:TOHO螺杆泵  PH(ORP)计  搅拌机  气动隔膜泵  TESCOM  压力调压阀